Bolli focuses on Vision Fluid
BOLI, FOCUS ON VISION‑BASED FLUID DISPENSING
Search All
BOLI, FOCUS ON VISION‑BASED FLUID DISPENSING
The vision dispensing machine's captured image jitters now and then, match scores swing, servos alarm without cause, and occasional missed dots defy explanation—if these ills track the shop's high-power equipment, firing whenever that side starts, odds are nine in ten it's not a broken machine but unhandled electrical interference.
Interference needs three things to take effect:interference source, propagation path, sensitive link. The most common shop-floor sources are inverters, servo drives, contactor coils, and switching supplies—high-frequency noise from switching races along power and ground lines; three paths exist—power-line conduction, spatial radiation, shared grounds; the sensitive link iscamera capture, signal acquisition, and controller. When all three line up, the fault fires on schedule.
Are the machine housing, cabinet doors, and camera brackets actually grounded where they should be?On site we've seen corroded ground rods with near-floating grounds pouring interference into signal loops, and shields grounded at both ends where unequal potentials drove circulating currents—blocking nothing while adding a problem. We've also seen neutral wires used as grounds: the machine runs, but the hazards stay buried in the system and need immediate correction.

Next, check the wiring。power lines and signal lines bundled together in parallel over long distances, the most common interference entry point; once the inverter starts, interference is directly fed into the camera cables and sensor cables. Lay signal lines in separate grooves with increased spacing, and use perpendicular crossings when crossing is unavoidable; camera lines and encoder lines useshielded twisted pairs, with the shield single-end grounded at the controller side.
On the source side, add arc suppressors to contactor coils, ground and filter inverters per manufacturer requirements, and slip ferrite rings onto signal lines to damp high frequencies. On the equipment side, vision dispensing machines like Bolli's pre-provision camera cables and encoder cablesshield grounding terminals, and for sensitive signals add when necessaryIsolation modules, keeping common-mode interference out.
the way to locate it:switch off the suspected interfering devices one by one; the one whose shutdown makes the fault disappear is the source。inverter start-stop is synchronized with image jitter, and you can basically pinpoint it. Do not start by replacing the camera or the main board, because replacing them will not suppress the conducted interference.

problems with the image itself and interference must be distinguished. Jitter caused by interference hasrandom and synchronized with the movement of large equipment;improper exposure and a dirty lensthe resulting gray and blurred image is stable and has nothing to do with which device is on or off,the image preprocessing article covered grayscale and threshold handling, rule out the parameter layer before thinking electrical,how to tune exposure and focus was also covered。
solid grounding, separated power/signal conduits, single-end shield grounding, sectioned power-down to find the source, and after the four steps most interference subsides. For recurring, patternless jitter and signal jumps, film the fault scene and call 13352947677 for Bolli Automation Co., Ltd. after-sales, who will visit withtroubleshoot section by section with an earth resistance tester, more practical than blindly swapping accessories.