how to adjust image graying after vision dispensing machinelight source brightness decay?

after using a vision dispensing machine for half a year, the image slowly grays and the recognition threshold starts to drift; many people's first reaction is to change the algorithm. most of the time the problem is not the algorithm - LED brightness naturally declines with usage time, and a darker image is an aging signal. check the light source first, then adjust parameters; reversing the order makes the decay problem messier.

rule out contamination first, then discuss decay

dust accumulation and oil mist are the most common false decay, industry materials mention that a few weeks can reduce output by twenty percent.power off first,用dip a lint-free cloth in optical cleaning fluid and wipe the diffusion board from the center outward, do not rub hard with dry tissue; only talk about aging if it remains dark after wiping. what Bolli after-sales commonly sees on-site is the light source surface board covered with a layer of oil mist; brightness returns immediately after wiping.

设备取像界面与light源面board实拍
the grayscale in the imaging interface directly reflects the light source status

how much decay cannot be judged by naked eye

LED is marked tountil brightness drops to seventy percent, the nominal lifespan is tens of thousands of hours, but decay accelerates once ambient temperature rises; above 40 degrees it can be two to three times faster; stations near drying tunnels and heat-generating equipment should be watched. human perception of light intensity is non-linear, and a few percentage points of dimming cannot be seen with the naked eye; automatic exposure light quietly compensates brightness, the image looks normal, but noise is creeping up and contrast is dropping - the algorithm's margin was lost long ago.a fixed-threshold recognition algorithm starts to drift after brightness drops by ten percent。

light源、景深适中-成像清晰
light source, moderate depth of field - clear imaging

make adjustments in order, do not max out in one step

after confirming decay, take four steps:clean first;再raise the brightness level- run daily in the mid-low range; long-term full brightness doubles light decay; first add a few levels to see the effect; thenadjust exposure light and gain, gain noise follows, recover within two steps manually; if threshold drift still cannot be suppressed after compensation, then换light源. high-speed stations use strobe trigger mode, lighting only at the exposure light instant, extending lifespan considerably. record grayscale values in the routine inspection sheet before and after each adjustment; decay is a gradual process, and only with records can the trend be seen.

海康相machine与自研light源安装实拍
the distance and angle between the camera machine and the light source also affect imaging brightness

workpiece dots are dense; slight image brightness dimming causes edge recognition to fail first; keep a close eye on the light source status. add image grayscale check to daily routine inspection, once a month is enough. how to select and light the light source,the article on light source selection and lighting plan has been written; basic adjustment of exposure light and focus,the article on camera machine exposure light focus can be read for reference。

the imaging Stability of Vision automatic dispensing equipment is half dependent on light source maintenance. when the image grays, do not rush to change the program; followcleaning, brightening, compensating, replacinggo through the sequence, and most stations can recover on the spot. for selection and after-sales, you can contactBolli Automation Co., Ltd.13352947677。

How to Adjust the Z-Axis Height of a Dispensing Machine? Previous: